| Security
grille controls access at both interior and exterior
openings. Applications include malls, commercial,
and industrial buildings.
SPECIFICATIONS
Note: This section includes commercial and institutional
overhead rolling grilles often used to separate
public from private premises. Check chart for
model numbers. Often specified options appear
in parentheses ( ).
PART 1 GENERAL
1.01 Furnish and
install Model(s)- EURO GRILLE as manufactured
by City-Gates.
1.02 Opening
preparation, access panels, finish or field painting,
electrical wiring, wire, conduit, fuses and disconnect
switches are in the Scope of Work of other divisions
or trades.
PART 2 PRODUCT
2.01 Materials
A. Grille curtain conforming
to the following:
1. Connecting Rings are .14 gauge
x 3/4" electro galvanized. Horizontal Tubes
1/2 OD by .18 gauge electro galvanized steel.
2. Bottom bar to be heavy duty
aluminum, reinforced with 3" x 2" x
3/16" aluminum angles for widths over 27'
-4".
B. The bottom bar will be 6
x 2 roll formed 14 gauge galvanized steel to match
curtain. Optional heavy duty aluminum extruded
tube or double angle aluminum.
C. Counterbalance Shaft Assembly
shall consist of steel pipe capable of supporting
curtain load with maximum deflection of 0.03"
per foot of width and helical torsion spring assembly
designed for proper balance of grille to insure
that effort to operate grille will not exceed
35 pounds. Ball or roller bearings to be furnished
at rotating support points. Provide wheel for
applying spring torque and for future adjustment.
Band springs for smaller doors.
D. Brackets shall be steel
plate not less than 3/16" thick with ball
or roller bearings at rotating support points,
bolted to guide assembly extension; support counter-balance
assembly and forms end closures.
E. Hood to be omitted unless
required (24 gauge galvanized steel) (0.4"
aluminum) (#24 gauge stainless steel). (Provide
supports as required to prevent excessive sag.)
F. Operation shall be push-up,
OR chain hoist, OR motor
operation |
|
1.
For grilles up to 24' -0" wide and 14' -4"
high, Model H listed motor
operator includes motor,
reducer, controller, limit switch, Motor
Mounted Interlock overload device, roller chain
drive and floor level disconnect for emergency
push-up operation. Controller and push-button
station or key switch are in NEMA 1 enclosures.
2. For grilles up to 37' -4"
wide and 14' -4" high Model MO motor
operator includes an open drip-proof motor
removable without affecting emergency operation
or setting of limit switches, heavy duty magnetic
controller, rotary limit switch, Motor
Mounted Interlock overload device, posi-lock brake
system, adjustable friction clutch, 24V control
circuit; all integral electrical components prewired
to terminal block for ease of field wiring, heavy
duty V-belt intermediate drive, #50 roller chain
and sprocket final drive, floor level disconnect
for emergency hand chain operation. UL listed
operator. Controller and push-button station or
key switch in NEMA 1 enclosure.
3. CG 2000 motor
system. Optional release System Furnish Manual
Release System with motor
operated grilles. Actuation of the pull handle,
after unlocking grille, disengages the motor
drive and causes grille to open partially. Release
of handle automatically returns to grille to normal
motor
operation.
G. Provide for cylinder locks
in bottom bar, locking at both jambs, operable
mall side (tenant side) (both sides) (furnish
with electric interlocks at guides if H operator
is used). Provide cylinder locking device on public
side and thumb turn on tenant side when used with
MO operator and Manual Release System. Standard
cylinders may be replaced with masterkeyed cylinders
(by others) if required. Consult factory for alternate
locking situations.
2.03 Finishes
Also available Exposed ferrous surfaces to be
primed.
PART 3 EXECUTION
3.01 Installation
A. Install rolling grilles in
accordance with instructions.
B. Installation shall be by authorized
distributor or representative.
3.02 Quality Assurance
A. Manufacturer shall supply
a certificate stating that all materials and finishes
will comply with the specifications.
|